PROFIBUS-DPV1 BUS MODULE

PROFIBUS for Thyro-S
for Thyro-A
for Thyro-AX


The bus modules are suitable for optional connection of up to 8 SCR power controllers of type Thyro-AX, Thyro-A and Thyro-S with a master in any desired order. As a slave bus station, the module only needs one address allowing several bus modules to be used on one bus at the same time. Data transmission includes setpoints and actual values amongst other parameters.

NEW:

With the same functional range, PROFIBUS DPV1 bus module is also available as a version for the choicefree connection of up to 2 power controllers and as a version for the choicefree connection of up to 4 power controllers.
 

KEY FEATURES

  • Optional connection of up to 8 SCR power controllers
  • Only one address required for each bus module
  • Access to setpoints, actual values and parameters of the SCR power controller
  • Transfer of actual values as floating-point numbers
  • Functional check by LEDs
  • Max. 8 free outputs
  • Control of Thyro-S with digital setpoints
  • Electrical power supply 24 VDC, 150 mA
  • Mounting on hat rail
  • UL & CE approval

ADDITIONAL FEATURES

The PROFIBUS DPV1 bus module is also available as a version for mains load optimization for Thyro-A and Thyro-AX power controllers. For further information, please see:

dASM Bus Module for Thyro-A
dASM Bus Module for Thyro-AX


PROFINET BUS MODULE

ETHERNET for Thyro-S
for Thyro-A
for Thyro-AX


The Ethernet bus module can connect to up to 8 power controllers of type Thyro-AX, Thyro-A and Thyro-S with a master in any desired order. Several bus modules can be used on one system. The power supply of the bus module comes from an external 24V DC voltage source (150mA), which is to be fed in (reverse polarity protected) at X11.1 (+) and X11.2 (ground). Several modules can be operated from one power supply. As short a ground connection as possible is needed at terminal X11.3 for EMC reasons.

KEY FEATURES

  • One Ethernet bus module which can switch between several Ethernet bus systems
  • Optional connection of up to 8 SCR power controllers
  • Access to setpoints, actual values and parameters of the SCR power controller
  • Transfer of actual values as floating-point numbers
  • Functional check by LEDs
  • 8 free application outputs X1 to X8 in each case terminal 5
  • C-rail assembly


ETHERNET/IP BUS MODULE

ETHERNET for Thyro-S
for Thyro-A
for Thyro-AX


The Ethernet bus module can connect up to 8 power controllers of type Thyro-AX, Thyro-A and Thyro-S with a master in any desired order. Several bus modules can be used on one system. The power supply of the bus module comes from an external 24V DC voltage source (150mA), which is to be fed in (reverse polarity protected) at X11.1 (+) and X11.2 (ground). Several modules can be operated from one power supply. As short a ground connection as possible is needed at terminal X11.3 for EMC reasons.

KEY FEATURES

  • One Ethernet bus module which can switch between several Ethernet bus systems
  • Optional connection of up to 8 SCR power controllers
  • Access to setpoints, actual values and parameters of the SCR power controller
  • Transfer of actual values as floating-point numbers
  • Functional check by LEDs
  • 8 free application outputs X1 to X8 in each case terminal 5
  • C-rail assembly


MODBUS TCP BUS MODULE

ETHERNET for Thyro-S
for Thyro-A
for Thyro-AX


The Ethernet bus module can connect up to 8 power controllers of type Thyro-AX, Thyro-A and Thyro-S with a master in any desired order. Several bus modules can be used on one system. The power supply of the bus module comes from an external 24V DC voltage source (150mA), which is to be fed in (reverse polarity protected) at X11.1 (+) and X11.2 (ground). Several modules can be operated from one power supply. As short a ground connection as possible is needed at terminal X11.3 for EMC reasons.

KEY FEATURES

  • One Ethernet bus module which can switch between several Ethernet bus systems
  • Optional connection of up to 8 SCR power controllers
  • Access to setpoints, actual values and parameters of the SCR power controller
  • Transfer of actual values as floating-point numbers
  • Functional check by LEDs
  • 8 free application outputs X1 to X8 in each case terminal 5
  • C-rail assembly


MODBUS RTU BUS MODULE

MODBUS for Thyro-S
for Thyro-A
for Thyro-AX


The bus modules are suitable for optional connection of up to 8 SCR power controllers in the Thyro-Family of products. As a slave bus station, the module only needs one address allowing several bus modules to be used on one bus at the same time

KEY FEATURES

  • Optional connection of up to 8 SCR power controllers
  • Only one address required for each bus module
  • Access to setpoints, actual values and parameters of the SCR power controller
  • Transfer of actual values as floating-point numbers
  • Functional check


DEVICENET BUS MODULE

DEVICENET for Thyro-S
for Thyro-A
for Thyro-AX


The bus modules are suitable for optional connection of up to 8 SCR power controllers of type Thyro-AX, Thyro-A and Thyro-S with a master in any desired order. As a slave bus station, the module only needs one address allowing several bus modules to be used on one bus at the same time. Data transmission includes setpoints and actual values amongst other parameters.

KEY FEATURES

  • Optional connection of up to 8 SCR power controllers
  • Only one address is required for each bus module
  • Access to setpoints, actual values and parameters of power controller
  • Transfer of actual values as floating-point numbers
  • 8 free outputs
  • Control of Thyro-S with digital setpoints
  • Power supply 24 VDC, 150 mA
  • Mounting on hat rail
  • UL / CE approval


CANOPEN BUS MODULE

CANOPEN for Thyro-S
for Thyro-A
for Thyro-AX


The bus modules are suitable for optional connection of up to 8 SCR Power Controllers in the Thyro-family of products. As a slave bus station, the module only needs one address allowing several bus modules to be used on one bus at the same time. Data transmission includes setpoints and actual values amongst other parameters.

KEY FEATURES

  • Optional connection of up to 8 SCR power controllers
  • Only one address required for each bus module
  • Access to setpoints, actual values and parameters of the SCR power controller
  • Transfer of actual values as floating-point numbers
  • Functional check by LEDs
  • 8 free outputs
  • Control of Thyro-S with digital setpoints
  • Electrical power supply 24 VDC, 150 mA
  • Mounting on hat rail
  • UL & CE approval
Close

Stay connected!

Hear about our upcoming webinars!


Legal Notice  |  Privacy Policy