Photo of XS Series Power Supply

AC-to-HVDC Single-Output Rack-Mount High-Voltage Power Supplies

The OLS10K series of single-output high-voltage power supplies meets the exacting requirements found in electron beam, ion beam, and x-ray systems, as well as ion and chemical vapor deposition, electrostatic precipitation, and other 24/7 production processes. 

Designed using the latest power switching IGBTs to ensure efficient and reliable operation over the full operating range, the OLS10K series will give exemplary performance in the most severe of electrical environments. The OLS10K series achieves an exceptionally high packing density for high-voltage power supplies of this power level, giving 169 W per Liter, 2.7 W per inch3. The 6 U construction allows operation at full power when close-mounted in a standard equipment rack, giving significant savings in rack space in large systems. Featuring the Arc Count and Extinguish (ACE) system for managing systems where load arcing is endemic, the OLS10K series has limits to prevent damage that may be caused by excessive arcing while allowing normal operation to continue. The OLS10K series features both analog and remote control (optional RS232) interfaces. A full set of commands is available over the RS-232 interface to control and monitor the operation of the power supply.


Model-Specific Downloads

OLS10K series brochure
OLS10K series brochure   JAPANESE
OLS10K series brochure   KOREAN
OLS10K series brochure   SIMPLIFIED CHINESE
 

Typical Applications Features
  • Electron beam
  • Ion beam 
  • X-ray
  • Lasers
  • HV pulse generator bias
  • HV amplifier bias
  • Electrostatic precipitation
  • Chemical purification
  • High packing density: 10 kW in 6 U rack mounted chassis
  • Output voltages from 1 to 80 kV
  • Parallel option to give 20 to 100 kW
  • Exceptional reliability in severe electrical environments
  • High stability
  • Arc Count and Extinguish (ACE)
  • Full local and remote control and monitoring
  • Analog or RS232 remote control
  • Voltage or current control
  • CE marked for EU LV directive 2006/95/EC
  • RoHS compliant to EU directive 2011/65/EU
  • Custom options available
Specifications
Input  
Voltage OLS10K: 208 VAC ±10% (187 to 229 VAC) 47 to 63 Hz 3 phase plus protective earth

OLS10KC: 380 VAC ±10% (342 to 418 VAC) 47 to 63 Hz 3 phase plus protective earth

OLS10KE: 400 VAC ±10% (360 to 440 VAC) 47 to 63 Hz 3 phase plus protective earth
Current OLS10K: Less than 36 A per phase
OLS10KC: Less than 22 A per phase
OLS10KE: Less than 22 A per phase
Output and Ordering Info Model No Input Voltage Output Voltage Output Current (Max) Output Power
  OLS10K-102 208 VAC 1 kV 10 A 10 kW
  OLS10K-202 208 VAC 2 kV 5 A 10 kW
  OLS10K-502 208 VAC 5 kV 2 A 10 kW
  OLS10K-103 208 VAC 10 kV 1 A 10 kW
  OLS10K-203 208 VAC 20 kV 500 mA 10 kW
  OLS10K-303 208 VAC 30 kV 333 mA 10 kW
  OLS10K-403 208 VAC 40 kV 250 mA 10 kW
  OLS10K-503 208 VAC 50 kV 200 mA 10 kW
  OLS10K-603 208 VAC 60 kV 166 mA 10 kW
  OLS10K-803 208 VAC 80 kV 125 mA 10 kW
  OLS10KC-102 380 VAC 1 kV 10 A 10 kW
  OLS10KC-202 380 VAC 2 kV 5 A 10 kW
  OLS10KC-502 380 VAC 5 kV 2 A 10 kW
   OLS10KC-103 380 VAC 10 kV 1 A 10 kW
  OLS10KC-203 380 VAC 20 kV 500 mA 10 kW
  OLS10KC-303 380 VAC 30 kV 333 mA 10 kW
  OLS10KC-403 380 VAC 40 kV 250 mA 10 kW
  OLS10KC-503 380 VAC 50 kV 200 mA 10 kW
  OLS10KC-603 380 VAC 60 kV 166 mA 10 kW
  OLS10KC-803 380 VAC 80 kV 125 mA 10 kW
  OLS10KE-102 400 VAC 1 kV 10 A 10 kW
  OLS10KE-202 400 VAC 2 kV 5 A 10 kW
  OLS10KE-502 400 VAC 5 kV 2 A 10 kW
  OLS10KE-103 400 VAC 10 kV 1 A 10 KW
  OLS10KE-203 400 VAC 20 kV 500 mA 10 kW
  OLS10KE-303 400 VAC 30 kV 333 mA 10 kW
  OLS10KE-403 400 VAC 40 kV 250 mA 10 kW
  OLS10KE-503 400 VAC 50 kV 200 mA 10 kW
  OLS10KE-603 400 VAC 60 kV 166 mA 10 kW
  OLS10KE-803 400 VAC 80 kV 125 mA 10 kW
Voltage Regulation (VDC) Line: Less than 0.01% +0.5 V change in output voltage for a 10% change in line voltage
Load: Less than 0.01% +0.5 V change in output voltage set point for a 0 to 100% change in load current
Voltage Ripple OLS10K:
Voltage mode: Less than 0.05% of rated voltage +2 V, peak to peak or less than 0.01% of rated voltage +1 V rms
Current mode: Less than 0.5% of rated voltage peak to peak or less than 0.1% of rated voltage rms
OLS10KC and OLS10KE:
Voltage mode: Less than 0.1% of rated voltage +2 V, peak to peak or less than 0.02% of rated voltage +1 V rms
Current mode: Less than 0.5% of rated voltage peak to peak or less than 0.1% of rated voltage rms
Current Regulation Line: Less than 0.5% of rated current for a ±10% change in line voltage
Load: Less than 0.5% of rated current for 0 to 100% change in output voltage
Min Voltage 5% of rated output voltage
The unit may be turned down below this level, but the specifications are not guaranteed below this level.
Calibration Calibration between voltage demand, ouput voltage and voltage monitor ±0.2% of setting or ±0.05% of rating, whichever is greater
Recovery Time Less than 200 ms to within 0.1% of previous operating level following a short circuit or arc
Max overshoot 2% of rated output voltage
Polarity Positive or negative to order

Environmental
Altitude Sea level to 2000 m (6500')
Limits The units have limits for over-temperature, over-voltage, fan failure, and current limit. Peak arc current is resistively limited.
Arc Count and Extinguish (ACE) Each time the ACE system detects an arc it blanks the supply off for a brief period to extinguish the arc. The unit is then allowed to recover. If more arcs occur, they are counted to determine the arc rate; if this exceeds a safe level, the power supply is shut down. The parameters are factory set to 25 arcs in any 5 second period.
EMC Intended for installation as a component of a system and is designed to meet:
  • EN55022 Class B for conducted and radiated emissions
  • EN61000-4-2 ESD - levels ±4 kV contact, ±8 kV air discharge
  • EN61000-4-4 fast transients on mains input - levels ±2 kV
  • EN61000-4-5 surges - levels ±2 kV line to earth, ±1 kV line to line
  • EN61000-4-8 magnetic fields - levels 30 A/m at 50/6 0Hz
  • EN61000-4-11 voltage dips, interruptions
The unit will not trip and recovers to normal operation after a disturbance as defined in SEMI F47-0706.
The EMC performance of the power supply can only be fully assessed when installed within, and as a part of, the final system.
Cooling The unit utilizes forced air cooling. Air is drawn in via the front panel slotted opening and through side panel vents. Ensure that within the rack there is a free air opening with a minimum effective area of 195 cm2 directly in front of the unit front panel slots. An additional free air opening with a minimum effective area of 195 cm2 is required for the side vents. Air flow from this additional free air opening to the side vents of the power converter must not be restricted. The expected air flow for each opening is approximately 50 liters per second. The maximum temperature of the air entering the unit must not exceed 40°C. The unit can dissipate up to 2 kW, therefore provision must be made to extract the exhaust air from the rack in order to prevent possible overheating.
Temperature Coefficient Less than 100 ppm per °C
Drift Less than 0.01% per hour after 1 hr warm up, typically less than 0.02% per 8 hr after 1 hr warm up, at constant load, line, and temperature
Operating Temperature 0 to +40°C (32 to +140°F)
Storage Temperature -20 to +70°C (-4 to +158°F)
Humidity 80% max relative humidity up to 31°C (88°F) reducing linearly to 50% at 40°C (104°F)
Non-condensing.
Safety The OLS10K high-voltage power supplies meet the requirements of the Low Voltage Directive (LVD) 2006/95/EC, by complying with BS EN61010-1:2001 when installed as a component part of other equipment. The units are CE marked accordingly. Designed to meet the general requirements of SEMI S2 for electrical safety
Safety Class Equipment Class 1
Usage Indoor use only
Metering Provided as part of an alpha-numeric display.
Voltages are displayed with a resolution of better than 0.5% of rated output. Current is displayed with a resolution of better than 1.5% of rated output.
Voltage and current set values can be displayed by pressing the relevant control potentiomenter.
Installation Category II (BS EN61010-1)
Pollution Degree 2 (BS EN61010-1)
Status Indication Uses the alpha-numeric display to show the reason for any trip condition.
RoHS Meets the requirements of EU Directive 2002/95/EC on the restriction of use of certain hazardous substances in electrical and electronic equipment (RoHS).

 

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.

This series is available in the following models.

Model Input
Voltage
Output
Voltage
Output
Current (Max)
Output
Power
OLS10K-102                 208 VAC           1 kV                 10 A      10 kW       
OLS10K-202 208 VAC 2 kV 5 A      10 kW
OLS10K-502 208 VAC 5 kV 2 A      10 kW
OLS10K-103 208 VAC 10 kV 1 A      10 kW
OLS10K-203 208 VAC 20 kV 500 mA      10 kW
OLS10K-303 208 VAC 30 kV 333 mA      10 kW
OLS10K-403 208 VAC 40 kV 250 mA       10 kW
OLS10K-503 208 VAC 50 kV 200 mA      10 kW
OLS10K-603 208 VAC 60 kV 166 mA 10 kW
OLS10K-803 208 VAC 80 kV 125 mA 10 kW
OLS10KC-102 380 VAC 1 kV 10 A 10 kW
OLS10KC-202 380 VAC 2 kV 5 A 10 kW
OLS10KC-502 380 VAC 5 kV 2 A 10 kW
OLS10KC-103 380 VAC 10 kV 1 A 10 kW
OLS10KC-203 380 VAC 20 kV 50 0mA 10 kW
OLS10KC-303 380 VAC 30 kV 333 mA 10 kW
OLS10KC-403 380 VAC 40 kV 250 mA 10 kW
OLS10KC-503 380 VAC 50 kV 200 mA 10 kW
OLS10KC-603 380 VAC 60 kV 166 mA 10 kW
OLS10KC-803 380 VAC 80 kV 125 mA 10 kW
OLS10KE-102 400 VAC 1 kV 10 A 10 kW
OLS10KE-202 400 VAC 2 kV 5 A 10 kW
OLS10KE-502 400 VAC 5 kV 2 A 10 kW
OLS10KE-103 400 VAC 10 kV 1 A 10 kW
OLS10KE-203 400 VAC 20 kV 500 mA 10 kW
OLS10KE-303 400 VAC 30 kV 333 mA 10 kW
OLS10KE-403 400 VAC 40 kV 250 mA 10 kW
OLS10KE-503 400 VAC 50 kV 200 mA 10 kW
OLS10KE-603 400 VAC 60 kV 166 mA 10 kW
OLS10KE-803 400 VAC 80 kV 125 mA 10 kW

Available Cables:
Part Number Description       
A1040958-3M0    OLS10K 3M HV Cables
A1040958-5M0 OLS10K 5M HV Cables 
A1040958-10M OLS10K 10M HV Cables

 

OLS10KD-103OLS10KD-103