For a sales quote, meeting request, evaluation unit, or other sales question, please fill in the form below:


Terms of Use | Privacy Policy
HITEK POWER® XR2000
Photo of XS Series Power Supply
   

2 KW X-RAY POWER SUPPLY RACKS

The XR2000 series incorporates a switching floating filament supply, allowing use of both large and small focus filament connections within an x-ray tube. The filament supply is automatically controlled by the integral beam loop. This series provides an RS-232 control interface and is based on the proven HiTek Power® IGBT converter, ensuring high efficiency and reliable operation.

Model-Specific Downloads

XR2000 series brochure
Download CAD .sat file
Download CAD .stp file
 
Features Typical Applications
  • 0 to -60 kv or -90 kV at up to 2 kW of output power
  • Constant power capability over 65 to 100% of HV output
  • Extensive tube and system protection functions
  • High stability after warmup, < 0.01% per 8 h, low Tc. < 100
    ppm per °C
  • Precise regulation, line and load < 0.05%, fast settling < 350 msec
  • Low ripple, < 0.25%
  • High accuracy filament floating on the high voltage
  • High accuracy filament controlled beam regulation                         · Emission accuracy: 1.66%
    · Regulation: 0.05%
    · Stability: 0.1% per 8 h
  • Robust IGBT converter design
  • RS-232 control interface
  • CE marked for EU LV directive 73/23/EEC
  • RoHS compliant unit available on request
  • X-ray fluorescence (XRF)
  • X-ray diraction (XRD)
  • X-ray reflectivity (XRR)
  • X-ray imaging (XRI)
  • Elemental analysis equipment
  • Industrial process x-ray systems
    · Process quality, safety,
    compliance
    · Materials monitoring
    · Food safety inspectio
  • Digital x-ray imaging and inspection
    · Industrial
    · Veterinary
    · Pharma, cellular, biotech
    · Security
Specifications
Polarity Negative
Specification range Specifications apply above 5% of rated output voltage and current
Electrical output
Power 2 kW, max, at full rated output voltage and current
Voltage 0 to -60 kV or 0 to -90 kV
Current 60 kV unit: 0 to 33 mA at 60 kV, increasing to 45 mA, max, at 45 kV; Constant power between 45 and 60 kV
90 kV unit: 0 to 22 mA at 90 kV, increasing to 33 mA, max, at 60 kV; Constant power between 60 and 90 kV
Ripple < 0.25% of setting plus 0.25% of rating, peak to peak
Electrical input
Voltage 230 VAC ±10% (207 to 253 VAC) 47 to 63 Hz, single phase and earth
Current Not exceeding 16 ARMS
Voltage regulation
Line < 0.05% change in output voltage for a 10% change in line voltage
Static load < 0.05% change in output voltage for a 5 to 100% change in output current
Dynamic load < 5% change in output voltage for a 5 to 100% change in output current, recovery to within 0.1% or 45 V (whichever
is greater) of previous setting within 350 msec
Current regulation
Line < 0.05% change in output current for a 10% change in line voltage
Load < 0.05% change in output current for a 60% change in rated output voltage
Filament specification
Voltage 12 VDC, max; referenced to the negative output voltage
Current 0.5 to 5 ADC
Stability and drift
Temperature coefficient < 100 ppm/°C
Drift < 0.1% of rating over an eight-hour period after 30 min warmup
Arc count and extinguish
ACE Each time the ACE system detects an arc, it blanks the supply off for a brief period to extinguish the arc. The unit is then allowed to recover. If more arcs occur, they are counted to determine the arc rate; if this exceeds a safe level, the power supply is shut down. The parameters are factory set.
Environmental
Operating temperature 0 to +40°C (50 to 104°F)
Storage temperature -20 to +70°C (-4 to 158°F)
Humidity 80% max relative humidity up to 31°C (88°F), reducing linearly to 50% at 40°C (104°F); non-condensing (ref BS EN61010-1)
Altitude Sea level to 2000 m (6500')
Cooling Fan assisted with fan fail detection. Air inlets at the sides of the unit with exhaust on the rear panel. Minimum air flow required is 3 m/sec at the air intake on the side panels.
Installation category II (BS EN61010)
Pollution degree 2 (BS EN61010)
Portability Non-portable
Safety, protection, and compliance
EMC This power supply is intended for installation as part of a system. Basic EMC filtering is provided.
RoHS The XR2000 is currently built to non-RoHS standard. This unit can, however, be configured to meet the
requirements of RoHS where significant customer demand requires it, although this will have an impact on delivery timescales.
Protection Programmable x-ray tube filament current limit
Programmable HV output power limiting
HV output arc count and extinguish (ACE)
HV energy reduction series resistance
HVPS over-temperature, over-voltage, fan failure, and AC input
Selectable filament output for dual filament x-ray tubes
Safety Meets the requirements of the Low Voltage Directive (LVD), 73/23/EEC, by complying with BS EN61010-1:2001 when installed as a component part of other equipment and is CE marked accordingly.
Safety class Equipment class 1
Usage Indoor use only
Metering Provided as part of an alphanumeric display; Voltages are displayed with a resolution > 0.5% of rated output.
Current is displayed with a resolution of > 1.5% of rated output.
Status indication Alphanumeric display shows the status of the interlock and the reason for any trip condition.




Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.