For a sales quote, meeting request, evaluation unit, or other sales question, please fill in the form below:


Terms of Use | Privacy Policy
HITEK POWER® XR1000
Photo of XS Series Power Supply
   

1 KW X-RAY POWER SUPPLY MODULE

The XR1000 series is a component power supply for industrial x-ray systems, elemental analysis equipment,
x-ray diffraction spectrometers, and materials process monitoring applications. It incorporates a floating filament supply that is automatically controlled by the integral beam loop. It is based on the proven HiTek Power IGBT converter, ensuring high efficiency and reliable operation. The XR1000 units are available with either an analog or RS-232 control interface.

Model-Specific Downloads

XR1000 series brochure
Download CAD .sat file
Download CAD .stp file
 
Features Typical Applications
  • 1 KW of output power
  • Extensive tube protection facilities
  • Robust IGBT converter design
  • Short-circuit and overload protection
  • High stability
  • High-accuracy beam current control
  • Low ripple
  • Analog or RS-232 interface
  • CE marked for EU LV directive 2006/95/EC
  • X-ray fluorescence (XRF)
  • X-ray diffraction (XRD)
  • X-ray reflectivity (XRR)
  • X-ray imaging (XRI)
Specifications
Output power 72 W, max, depending on model (constant power available)
Output voltage 0 to -60 kV or 0 to -90 kV
Output current 60 kV unit: 0 to 16 mA
90 kV unit: 0 to 11 mA
Input voltage 230 VAC ±10% (207 to 253 VAC) 47 to 63 Hz, single phase and earth
Input current Not exceeding 12ARMS
Polarity Negative
Specification range Specifications apply above 5% of rated output voltage and current
Ripple < 0.25% of setting plus 0.25% of rating, peak to peak
Arc Count and Extinguish
(ACE)
Each time the ACE system detects an arc, it blanks the supply off for a brief period to extinguish the arc. The unit is then allowed to recover. If more arcs occur, they are counted to determine the arc rate; if this exceeds a safe level, the power supply is shut down. The parameters are factory set.
Metering Provided as part of an alphanumeric display; Voltages are displayed with a resolution better than 0.5% of rated output. Current is displayed with a resolution of better than 1.5% of rated output
Status indication The alphanumeric display shows the status of the interlock and the reason for any trip condition.
Voltage regulation
Line < 0.05% change in output voltage for a 10% change in line voltage
Static load < 0.05% change in output voltage for a 5 to 100% change in output current
Dynamic load < 5% change in output voltage for a 5 to 100% change in output current, recovery to within 1% of previous setting within 200 msec
Beam current regulation
Line < 0.05% change in output current for a 10% change in line voltage
Load < 0.05% change in output current for a 60% change in rated output voltage
Stability and drift
Temperature coefficient < 100 ppm/°C
Drift < 0.1% of rating over an eight-hour period after 30 min warmup
Filament specification
Voltage 8 VDC, max, referenced to the negative output voltage
Current 0.5 to 5 ADC
Environemental
Operating temperature 0 to +40°C (50 to 104°F)
Storage temperature -20 to +70°C (-4 to 158°F)
Humidity 80% max relative humidity up to 31°C (88°F), reducing linearly to 50% at 40°C (104°F); non-condensing (ref BS EN61010-1)
Altitude Sea level to 2000 m (6500')
Cooling Fan assisted with fan fail detection. Air inlets at the sides of the unit with exhaust on the rear panel. Minimum air flow required is 3 m/sec at the air intake on the side panels.
Usage Indoor use only
Installation category II (BS EN61010)
Pollution degree 2 (BS EN61010)
Portability Non-portable
Safety, protection, and compliance
EMC This power supply is intended for installation as part of a system. Basic EMC filtering is provided.
RoHS The XR1000 is currently built to non-RoHS standard. This unit can, however, be configured to meet the requirements of RoHS where significant customer demand requires it, although please note that this will have an impact on delivery timescales.
Protection Over-temperature
Over-voltage
Fan failure detection
Filament current limit
Series output resistance
Safety Meets the requirements of the Low Voltage Directive (LVD), 2006/95/EC, by complying with BS EN61010-1 when installed as a component part of other equipment and is CE marked accordingly
Safety class Equipment class 1




Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.