OLS10KD Series
Photo of XS Series Power Supply

10 kW High Voltage Power Supplies

The OLS10KD series of high voltage power supplies recognizes the requirement for high stability and very low ripple over a wide range of output voltages. This is achieved by combining the high power, 10 kW supply with a low power, 1 kW supply in the same chassis. The outputs of these are coupled together so that either can be used. For high voltages, usually above 10% of the maximum, the high energy (HE) supply is used; for voltages below 10%, the low energy (LE) supply is used. The LE supply has superior ripple and regulation at the lower voltages and maintains this down to a few hundred volts or less.

The OLS10KD series meets the exacting requirements found in electron- and ion-beam systems, ion implantation and X-ray systems. Designed using the latest power switching IGBTs to ensure efficient and reliable operation over the full operating range, the OLS10KD series will give exemplary performance in the most severe of electrical environments. The OLS10KD series achieves an exceptionally high packing density for high voltage power supplies of this power level, giving 169 W/l, 2.7 W/in3.


Model-Specific Downloads

OLS10KD series brochure


 
Typical Applications Features
  • Electron-beam systems
  • Ion-beam systems
  • Ion implantation
  • X-ray equipment
  • Wide dynamic range with dual supply configuration
  • Output voltages from 10 kV to 80 kV for high range
  • Output voltages from 1 kV to 10 kV for low range
  • High packing density: 10 kW in 6U rack-mounted chassis
  • Exceptional reliability in severe electrical environments
  • High stability
  • Arc count and extinguish (ACE)
  • Full Local and Remote Control and Monitoring
  • Analogue or RS232 remote control
  • Voltage or Current control
  • CE Marked for EU LV Directive 2006/95/EC
  • RoHS Compliant to EU Directive 2011/65/EU
  • Custom Options Available
Specifications
Input  
Voltage OLS10KD: 208 VAC ±10% (187 VAC to 229 VAC) 47-63 Hz 3 phase plus protective earth
OLS10KDC: 380 VAC ±10% (342 VAC to 418 VAC) 47-63 Hz 3 phase plus protective earth
OLS10KDE: 400 VAC ±10% (360 VAC to 440 VAC) 47-63 Hz 3 phase plus protective earth
Current Less than 36 A per phase
Output and Ordering Info Model No Input Voltage Output Voltage Output Current (Max) Output Power
  OLS10KD-103 208 VAC 10 kV 1 A 10 kW
  OLS10KD-203 208 VAC 20 kV 500 mA 10 kW
  OLS10KD-303 208 VAC 30 kV 333 mA 10 kW
  OLS10KD-403 208 VAC 40 kV 250 mA 10 kW
  OLS10KD-503 208 VAC 50 kV 200 mA 10 kW
  OLS10KD-603 208 VAC 60 kV 166 mA 10 kW
  OLS10KD-803 208 VAC 80 kV 125 mA 10 kW
  OLS10KDC-103 380 VAC 10 kV 1 A 10 kW
  OLS10KDC-203 380 VAC 20 kV 500 mA 10 kW
  OLS10KDC-303 380 VAC 30 kV 333 mA 10 kW
  OLS10KDC-403 380 VAC 40 kV 250 mA 10 kW
  OLS10KDC-503 380 VAC 50 kV 200 mA 10 kW
  OLS10KDC-603 380 VAC 60 kV 166 mA 10 kW
   OLS10KDC-803 380 VAC 80 kV 125 mA 10 kW
  OLS10KDE-103 400 VAC 10 kV 1 A 10 kW
  OLS10KDE-203 400 VAC 20 kV 500 mA 10 kW
  OLS10KDE-303 400 VAC 30 kV 333 mA 10 kW
  OLS10KDE-403 400 VAC 40 kV 250 mA 10 kW
  OLS10KDE-503 400 VAC 50 kV 200 mA 10 kW
  OLS10KDE-603 400 VAC 60 kV 166 mA 10 kW
  OLS10KDE-803 400 VAC 80 kV 125 mA 10 kW
Voltage Regulation (VDC) High and low range:
Line: Less than 0.05% +0.5 V change in output voltage for a 10% change in line voltage
Load: Less than 0.05% +0.5 V change in output voltage set point for a 0 to 100% change in load current
Voltage Ripple High and low range:
Voltage mode: Less than 0.05% of rated voltage +2 V, peak-to-peak or less than 0.01% of rated voltage +1V, RMS
Current mode: Less than 0.5% of rated voltage peak-to-peak or less than 0.1% of rated voltage RMS
Current Regulation High and low range:
Line: Less than 0.5% of rated current for a ±10% change in line voltage
Load: Less than 0.5% of rated current for 0 to 100% change in output voltage
Calibration Calibration between voltage demand, ouput voltage, and voltage monitor ±0.2% of setting or ±0.05% of rating, whichever is greater
Recovery Time Less than 200 ms to within 0.1% of previous operating level following a short circuit or arc
Max overshoot 2% of rated output voltage
Polarity Positive or negative to order
Both HE and LE will be of the same polarity.
Specification Range Specifications apply above 5% of rated output voltage for both HE and LE supplies. The output can be controlled down to less than 0.25% of rated output voltage.

Environmental
Temperature Coefficient Less than 100 ppm per°C
Drift Less than 0.01% per hour after 1 hr warm up, typically less than 0.02% per 8 hr after 1 hr warm up, at constant load, line, and temperature.
Operating Temperature 0°C to+ 40°C
Storage Temperature -20°C to +70°C
Humidity 80% max relative humidity up to 31°C, reducing linearly to 50% at 40°C
Non-condensing (ref BS EN61010-1)
Safety The OLS10KD high voltage power supplies meet the requirements of the low voltage directive, LVD, 2006/95/EC, by complying with BS EN61010-1:2001 when installed as a component part of other equipment. It is CE-marked accordingly.
Designed to meet the general requirements of SEMI S2 for electrical safety
Safety Class Equipment class 1
Usage Indoor use only
Metering Provided as part of an alpha-numeric display
Voltages are displayed with a resolution of better than 0.5% of rated output. Current is displayed with a resolution of better than 1.5% of rated output.
Voltage and current set values can be displayed by pressing the relevant control potentiomenter.
Installation Category II (BS EN61010-1)
Pollution Degree 2 (BS EN61010-1)
Status Indication Uses the alpha-numeric display to show the reason for any trip condition.
RoHS The OLS10KD series meets the requirements of EU directive 2002/95/EC on the restriction of use of certain hazardous substances in electrical and electronic equipment (RoHS).
Altitude Sea level to 2000 m (6500')
Limits The units have limits for over-temperature, over-voltage, fan failure, and current limit. Peak arc current is resistively limited 40 A at full HE output voltage.
Arc Count and Extinguish (ACE) Each time the ACE system detects an arc, it blanks the supply off for a brief period to extinguish the arc. The unit is then allowed to recover. If more arcs occur, they are counted to determine the arc rate; if this exceeds a safe level, the power supply is shut down. The parameters are factory-set to 25 arcs in any 5 sec period.
EMC The OLS10KD series is intended for installation as a component of a system and is designed to meet:
  • EN55022 Class B for conducted and radiated emissions
  • EN61000-4-2 ESD - levels ±4kV contact, ±8kV air discharge
  • EN61000-4-4 fast transients on mains input - levels ±2kV
  • EN61000-4-5 surges - levels ±2kV line to earth, ±1kV line to line
  • EN61000-4-8 magnetic fields - levels 30A/m at 50/60Hz
  • EN61000-4-11 voltage dips, interruptions
The unit will not trip and recovers to normal operation after a disturbance as defined in SEMI F47-0706.
The EMC performance of the power supply can only be fully assessed when installed within, and as a part of, the final system.
Cooling The unit utilizes forced-air cooling. Air drawn in via the front panel louvered opening and through side panel vents. Ensure that within the rack there is a free air opening with a min effective area of 195 cm2 directly in front of the unit front panel louvre. An additional free air opening with a min effective area of 195 cm2 is required for the side vents. Air flow from this additional free air opening to the side vents of the power conrter must not be restricted. The expected air flow for each opening is approximately 50 l per sec. The max temperature of the air entering the unit must not exceed 40°C.

The unit can dissipate up to 2 kW; therefore, provision must be made to extract the exhaust air from the rack in order to prevent possible overheating.

 

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.

This series is available in the following models.

Model Input
Voltage
Output
Voltage
Output
Current (Max)
Output
Power
OLS10KD-103 208 VAC 10 kV 1A 10kW
OLS10KD-203 208 VAC 20 kV 500mA 10kW
OLS10KD-303 208 VAC 30 kV 333mA 10kW
OLS10KD-403 208 VAC 40 kV 250 mA 10 kW
OLS10KD-503 208 VAC 50 kV 200 mA 10 kW
OLS10KD-603 208 VAC 60 kV 166 mA 10 kW
OLS10KD-803 208 VAC 80 kV 125 mA 10 kW
OLS10KDC-103 380 VAC 10 kV 1 A 10 kW
OLS10KDC-203 380 VAC 20 kV 500 mA 10 kW
OLS10KDC-303 380 VAC 30 kV 333 mA 10 kW
OLS10KDC-403 380 VAC 40 kV 250 mA 10 kW
OLS10KDC-503 380 VAC 50 kV 200 mA 10 kW
OLS10KDC-603 380 VAC 60 kV 166 mA 10 kW
OLS10KDC-803 380 VAC 80 kV 125 mA 10 kW
OLS10KDE-103 400 VAC 10 kV 1 A 10 kW
OLS10KDE-203 400 VAC 20 kV 500 mA 10 kW
OLS10KDE-303 400 VAC 30 kV 333 mA 10 kW
OLS10KDE-403 400 VAC 40 kV 250 mA 10 kW
OLS10KDE-503 400 VAC 50 kV 200 mA 10 kW
OLS10KDE-603 400 VAC 60 kV 166 mA 10 kW
OLS10KDE-803 400 VAC 80 kV 12 5mA 10 kW

 

 

OLS10KD-103OLS10KD-103