OL600W Series
Photo of XS Series Power Supply

AC-to-HVDC Single Output Rack-Mount High Voltage Power Supplies

The OL600W series range of single output high voltage power supplies meets the exacting requirements found in electron beam, ion beam, and x-ray systems, as well as ion and chemical vapor deposition, electrostatic precipitation, and other 24/7 production processes. Designed using the latest power switching IGBTs to ensure efficient and reliable operation over the full operating range, the OL600W series will give excellent performance in the most severe of electrical environments. The 1 U construction (2 U for 80 kV units) allows operation at full power when close mounted in a standard equipment rack, giving significant savings in rack space in large systems. Please note that the 80 kV unit utilizes an encapsulated HV section.

Model-Specific Downloads

OL600W series brochure
Download CAD .sat file
Download CAD .stp file
 
Typical Applications Features
  • Electron beam
  • Ion beam
  • X-ray
  • Lasers
  • HV pulse generator bias
  • HV amplifier bias
  • Electrostatic precipitation
  • Chemical purification
  • Output voltages from 1 kV to 80 kV
  • High packing density: 600 W in 1 U (80 kV in 2 U)
  • High stability
  • Exceptional reliability
  • Arc count and extinguish (ACE)
  • Full local and remote control monitoring
  • Voltage or curent control
  • Complies with SEMI F47 standard
  • CE marked for EU LV directive 2006/95/EC
  • RoHS compliant to EU directive 2011/65/EU
  • Custom options available
Specifications
Input  
Voltage 185 to 225 VAC or 103 to 127 VAC (auto range aelection). Range does not change after power up. 47 to 63 Hz single phase and earth.
Current (mA) Not exceeding 6 A rms (185 to 255 VAC)
Not exceeding 12 A rms (103 to 127 VAC)
Output and Ordering Info Model No Output Voltage Output Current Output Power

 
OL600W-102 1 kV 400 mA 600 W
  OL600W-502 5 kV 80 mA 600 W
  OL600W-103 10 kV 40 mA 600 W
  OL600W-203 20 kV 20 mA 600 W
  OL600W-303 30 kV 13.3 mA 600 W
  OL600W-403 40 kV 10 mA 600 W
  OL600W-503 50 kV 8 mA 600 W
  OL600W-603 60 kV 6.7 mA 600 W
  OL600W-803 80 kV 5 mA 600 W
Programming & Controls All Types
Voltage regulation (VDC) Line: less than 0.05% ±0.5 V change in input voltage for a 10% change in line voltage
Load: less than 0.05% ±0.5 V change in input voltage for a 0 to100% change in load current
Voltage ripple Voltage mode: less than 0.1% of rated output voltage +2 V, peak to peak or less than 0.02% of rated output voltage ±0.5 V rms
Current mode: less than 0.5% of rated output voltage +2 V, peak to peak or less than 0.1% of rated output voltage ±0.5V rms
Current regulation Line: less than 0.5% of rated output current for a 10% change in line voltage
Load: less than 0.5% of rated output current for a 0 to 100% change in output voltage

Environmental
Temperature coefficient Less than 100 ppm per °C
Operating temperature 0 to + 40°C (32 to 140°F)
Storage temperature -20 to +70°C (-4 to 158°F)
Humidity 80% maximum relative humidity up to 31°C (37°F) reducing linearly to 50% at 40°C (104°F). Non-condensing.
Safety CE marked to meet the requirements of the Low Voltage Directive, 2006/95/EEC, by complying with BS EN61010-1 when installed as a component part of compliant equipment.
Safety class Equipment Class 1
Usage Indoor use only
Installation category II (BSEN61010)
Pollution degree 2 (BSEN61010)
RoHS Meets the requirements of EU Directive 2011/65/EU on the restriction of use of certain hazardous substances in electrical and electronic equipment.
Metering Provided as part of an alphanumeric display.  Votlages are displayed with a resolution better than 0.5% of rated output. Current is displayed with a resolution of better than 1.5% of rated output.  Voltage and current set values can be displayed by pressing the relevant control potentiometer.
Status indication Uses the alphanumeric display to show the reason for any trip condition
Altitude Sea level to 2000 m (6500')
Protection The units are fully protected against flashover and continuous short circuit (no trip)
EMC The EMC performance of the power supply can only be fully assessed when installed within and as part of the final system.
Cooling Fan assisted with fan fail detection. Air inlets at the rear of the unit, exhaust on the side panels and top cover. Minimum air flow required is 3 m/s at the input to the fan. For slide mounting a 15 mm gap shall be provided above the unit for air exhaust if the side air vents are blocked. For shelf mounting the 1 U, no gap is required above or below the unit provided the side air vents are clear by at least 15 mm. The 2 U requires a 15 mm gap above the unit as well.

 

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.