For a sales quote, meeting request, evaluation unit, or other sales question, please fill in the form below:


Terms of Use | Privacy Policy
OL400W Series
Photo of XS Series Power Supply

High Voltage Power Supply Modules

The Series OL400W range of single output high voltage power supplies meets the exacting requirements found in electron and ion beam systems.  Designed using the latest power switching IGBTs to ensure efficient and reliable operation over the full operating range, the Series OL400W will give excellent performance in the most severe of electrical environments.  The 1U construction (2U for 80kV units) allows operation at full power when close mounted in a standard equipment rack, giving significant savings in rack space in large systems.  Please note that the 80kV unit utilizes an encapsulated HV section.

Model-Specific Downloads

OL400W series brochure
Download CAD .sat file
Download CAD .stp file
 
Typical Applications Features
  • Ion implantation
  • Grounded filament X-ray
  • Electron microscopes
  • Insulation testing
  • Output voltages from 1kV to 80kV
  • High packing density – 400W in 1U (2U for 80kV)
  • Exceptional reliability
  • Complies with SEMI F47 standard
  • High stability
  • Arc Count and Extinguish (ACE)
  • CE marked
  • RoHS Compliant to EU Directive 2011/65/EU
  • Full Local and Remote Control and Monitoring
  • Voltage or Current control
  • Positive or negative polarity units available
  • Custom options available
Specifications
Input  
Voltage 185VAC to 225VAC or 103VAC to 127VAC (Auto Range Selection).  Range does not change after power up.  47-63hz single phase and earth.
Current (mA) Not exceeding 5A rms (185VAC to 255VAC)
Not exceeding 10A rms (103VAC to 127VAC)
Output and Ordering Info Model No Output Voltage Output Current Output Power

 
OL400W-102 1kV 400mA 400W
  OL400W-502 5kV 80mA 400W
  OL400W-103 10kV 40mA 400W
  OL400W-203 20kV 20mA 400W
  OL400W-303 30kV 13.3mA 400W
  OL400W-403 40kV 10mA 400W
  OL400W-503 50kV 8mA 400W
  OL400W-603 60kV 6.7mA 400W
  OL400W-803 80kV 5mA 400W
Programming & Controls All Types
Voltage regulation (VDC) Line: less than 0.05% ±5V change in input voltage for a 10% change in line voltage
Load:less than 0.05% ±5V change in input voltage for a 0 to100% change in load current
Voltage ripple Voltage mode: less than 0.1% of rated output voltage +2V, peak to peak or less than 0.02% of rated output voltage ±0.5V, rms
Current mode: less than 0.5% of rated output voltage +2V, peak to peak or less than 0.1% of rated output voltage ±0.5V, rms
Current regulation Line: less than 0.5% of rated output current for a 10% change in line voltage
Load: less than 0.5% of rated output current for a 0 to 100% change in output voltage

Environmental
Temperature coefficient Less than 100ppm/°C
Operating temperature 0°C to+ 40°C (32°F to 140°F)
Storage temperature -20°C to +70°C (-4°F to 158°F)
Humidity 80% maximum relative humidity up to 31°C, reducing linearly to 50% at 40°C. Non-condensing. (ref. BS EN61010-1)
Safety Meets the requirements of the Low Voltage Directive, 2006/95/EEC, by complying with BS EN61010-1 when installed as a component part of compliant equipment.  Units are CE marked accordingly.
Safety class Equipment class 1
Usage Indoor use only
Installation category II (BSEN61010)
Pollution degree 2 (BSEN61010)
RoHS The Series OL400W meets the requirements of EU Directive 2011/65/EU on the Restriction of use of certain Hazardous Substances in electrical and electronic equipment (RoHS).
Metering Provided as part of an alphanumeric display.  Votlages are displayed with a resolution better than 0.5% of rated output.  Current is displayed with a resolution of better than 1.5% of rated output.  Voltage and current set values can be displayed by pressing the relevant control potentiometer.
Status indication Uses the alphanumeric display to show the reason for any trip condition.
Altitude Sea level to 2000 metres (6500 feet)
Protection The units are fully protected against flashover and continuous short circuit (no trip)
EMC The Series MHX is intended for installation as a component of a system.  Basic EMC filtering is provided.
Cooling Fan assisted with fan fail detection.  Air inlets at the rear of the unit, exhaust on the side panels and top cover.  Minimum air flow required is 3m/s at the input to the fan.
For slide mounting a 15mm gap shall be provided above the unit for air exhaust if the side air vents are blocked.
Flor shelf mounting no gap is required above or below the unit provided the side air vents are clear by at least 15mm.

 

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.