For a sales quote, meeting request, evaluation unit, or other sales question, please fill in the form below:


Terms of Use | Privacy Policy
MH60 Series
Photo of XS Series Power Supply

Versatile High Voltage Power Supply Modules

The Series MH60 is a range of versatile high voltage power supply modules suitable for specification in OEM equipment.  Powered from 24V DC, they supply up to 60W output and allow full range control and monitoring of output voltage and current. Custom versions can be produced for specific requirements.

Model-Specific Downloads

MH60 series brochure      JAPANESE
Download CAD .sat File
Download CAD .stp File
 
Typical Applications Features
  • Wide angle, high definition CRTs
  • X-ray equipment
  • Insulation and materials testing
  • Projection
  • 60 W output power
  • High reliability
  • 24 V DC powered
  • Range of outputs available
  • Positive or negative polarity
  • Short circuit and flashover protection
  • Remotely controllable
  • V & I control
  • V & I monitor
  • LED status indication
  • Low ripple
  • RoHS compliant to 2011/65/EU
  • CE marked
Specifications
Input  
Voltage +24 V DC (±10%)
Current (mA) 4 A max
Output and Ordering Info Model No Output Voltage Output Current

 
MH60/303 30 kV 2 mA
 
  MH60/403 40 kV 1.5 mA
  MH60/503 50 kV 1.2 mA
Voltage regulation (VDC) Line: less than 0.01% for a 10% change in input voltage
Load: less than 0.01% ±1 V no load to full load
Ripple Less than 0.05% ±10 V peak to peak
Current regulation Line: less than 0.01% for a 10% change in input voltage
Load: less than 0.01% ±1 μA for a 50% voltage change
Programming & Controls All Types
Monitors Voltage: 0 to 10 V ±0.25% ±5mV for 0 to 50 kV
Current: 0 to 10 V ±0.25% ±5mV for 0 to 1.2 mA
Note: each monitor has a series output resistor of 1 kΩ
Voltage control 0 to 10 V for 0 to 50 kV accuracy ±0.25% ±10 V
Current control 0 to 10 V for 0 to 1.2 mA  accuracy ±0.25% ±1 μA
Control The power supply is operated via the 9-way D-type connector situated on the rear panel. Full control and monitoring functions are available by this method

Environmental
Temperature coefficient 100ppm/°C over operating temperature range. Applies to voltage control, voltage monitor, and current monitor
Operating temperature 0°C to +45°C
Storage temperature -20°C to +60°C
Humidity 85% maximum relative humidity non-condensing
Safety The Series MH60 meets the requirements of the Low Voltage Directive (LVD), 2006/95/EC, by complying with BS EN61010 when it is installed as a component part of compliant equipment. It is CE marked accordingly.
RoHS The Series MH60 meets the requirements of EU Directive 2002/95/EC on the Restriction of use of certain Hazardous Substances in electrical and electronic equipment (RoHS)
Altitude Sea level to 2000 m (6500 ft)
Protection The units are fully protected against flashover and continuous short circuit (no trip)
EMC The Series MH60 is intended for installation as a component of a system. Basic EMC filtering is provided.
Cooling Free convection (no fan)
Installation category 1 (BS EN61010-1)
Pollution degree 2 (BS EN61010-1)

Available Cables:
Part Number    Description                                  
33400206-00    MH60 1M HV Cable
33400206-01     MH60 3M HV Cable
33400206-02    MH60 5M HV Cable

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.