For a sales quote, meeting request, evaluation unit, or other sales question, please fill in the form below:


Terms of Use | Privacy Policy
MV2000 Series
Photo of XS Series Power Supply

 High Voltage Rack Mount Power Supplies

The Series MV2000 range of high performance power supplies offers output voltages ranging from 20V to 300V with a maximum output power of 2kW in a compact 1U 19" rack-mountable chassis.

Parallel/series operation of units can be easily configured to provide higher output power levels to suit specific customer applications and/or provide n+1 redundancy.  The Series MV2000 incorporates a power factor corrector enabling the units to operate across a wide range of mains input voltages.  Control and monitoring is available both locally via the front panel and remotely via the rear panel user interface. 

Custom interface designs can be provided, making the MV2000 range a flexible solution for all your industrial power supply needs.  These include isolation (up to 1kV DC) and RS232.


Model-Specific Downloads

MV2000 series brochure
Download CAD .sat file
Download CAD .stp file

 
Typical Applications Features
  • X-ray equipment
  • Component testing
  • Heaters
  • Magnets
  • Battery management
  • Ion implantation
  • Automated test
  • 2kW output power
  • Output voltages from 20V to 300V
  • High packing density - 2kW in 1U
  • Parallel/series operation
  • Stackable, cooling is front to rear
  • Active Power Factor Correction
  • Custom options available
  • CE marked
  • RoHS compliant to 2011/65/EU
Specifications
Input  
Voltage 185VAC to 255VAC 47-63Hz single phase plus protective earth, operation below 185VAC is possible with linear power de-rating down to 1kW at 85VAC.
Current (mA) Not exceeding 13A rms (185VAC to 255VAC), harmonics are controlled with active power factor correction.
Output and Ordering Info Model No Output Voltage Output Current (Max) Output Power

 
MV2000-200 20V 100A
 
2kW
  MV2000-300 30V 66.5A 2kW
  MV2000-400 40V 50A 2kW  
  MV2000-500 50V 40A 2kW    
  MV2000-600 60V 33A 2kW    
  MV2000-700 70V 28.5A 2kW    
  MV2000-800 80V 25A 2kW    
  MV2000-900 90V 22A 2kW    
  MV2000-101 100V 20A 2kW    
  MV2000-111 110V 18A 2kW    
  MV2000-121 120V 16.5A 2kW    
  MV2000-131 130V 15A 2kW    
  MV2000-141 140V 14A 2kW    
  MV2000-151 150V 13A 2kW    
  MV2000-161 160V 12.5A 2kW    
  MV2000-171 170V 12A 2kW    
  MV2000-181 180V 11A 2kW    
  MV2000-191 190V 10.5A 2kW    
  MV2000-201 200V 10A 2kW    
  MV2000-211 210V 9.5A 2kW    
  MV2000-221 220V 9A 2kW    
  MV2000-231 230V 8.5A 2kW    
  MV2000-241 240V 8A 2kW    
  MV2000-251 250V 8A 2kW    
  MV2000-261 260V 7.5A 2kW    
  MV2000-271 270V 7.5A 2kW    
  MV2000-281 280V 7A 2kW    
  MV2000-291 290V 7A 2kW    
  MV2000-301 300V 6.5A 2kW    
Voltage regulation (VDC) Line: less than 0.05% deviation in output voltage set poitn for a 10% change in supply line voltage
Load: less than 0.1% deviation in output voltage set point for a 0 to 100% change in load current
Output ripple Voltage mode: Less than 0.1% peak to peak of rated output voltage +50mV peak to peak
Current mode: Less than 0.2% peak to peak of rated output current +50mA peak to peak
Output noise Less than 300mV up to 20MHz
Current regulation Line: less than 0.1% deviation in output current set point for a 10% change in supply line voltage
Load: less than 0.1% deviation in output current set point for a 0 to 100% change in output votlage
Polarity All models provide positive polarity, The output can be isolated from the chassis (by up to 900VDC) to provide negative outputs if required.  Control signals are referenced to the negative output.
Specification range Specifications apply above 5% of rated output voltage.  The output can be controlled down to less than 0.25% of rated output voltage.
Transient response Response for a 10%-90% or 90%-10% step change in load.  Overshoot/undershoot less than 2% of rated output.  Recovery to within 0.1% of rated output less than 10ms
Programming & Controls All Types
Monitors Voltage: 0 to 10V ±1% for 0 to rated output voltage
Current: 0 to 10V ±1% for 0 to rated output current
Note: each monitor has a series output resistor of 1kΩ
Voltage control 1 = 0 to 10V for 0 to rated output voltage, accuracy ±1% of rated voltage
2 = via remote potentiometer minimum resistance 9kΩ
3 = via internal potentiometer
Current control 1 = 0 to 10V for 0 to rated output current, accuracy ±1% of rated voltage
2 = via remote potentiometer minimum resistance 9kΩ
3 = via internal potentiometer
Note: any combination of V and I control may be used
Control The power supply is operated via the 15-way D-type connector situated on the rear panel.  Full control and monitoring functions are available by this method

Environmental
Temperature coefficient 100ppm/°C (0.01%/°C)
Operating temperature 0°C to+ 40°C
Storage temperature -20°C to +70°C
Humidity 80% maximum relative humidity up to 31°C, reducing linearly to 50% at 40°C.  Non-condensing (ref NS EN61010-1)
Safety Meets the requirements of the Low Voltage Directive, 2006/95/EC, by complying with BS EN61010-1 when installed as a component part of compliant equipment.  Units are CE marked accordingly
Safety class Equipment class 1
Usage Indoor use only
Installation category II (BSEN61010)
Pollution degree 2 (BSEN61010)
Portability Non-portable
RoHS The Series MV2000 meets the requirements of EU Directive 2011/65/EU on the Restriction of use of certain Hazardous Substances in electrical and electronic equipment (RoHS)
Metering Provided as part of an alphanumeric display.  Voltages are displayed with a resolution of better than 0.5% of rated output.  Current is displayed with a resolution of better than 1.5% of rated output.  Voltage and current set values can be displayed by pressing the relevant front panel control potentiometer.
Status indication Uses the alphanumeric display to show the reason for any trip condition
Altitude Sea level to 2000 metres (6500 feet)
Protection The units are fully protected against flashover and continuous short circuit (no trip)
EMC The Series MV2000 is intended for installation as a component of a system is designed to meet:
EN55022 Class B for conducted and radiated emissions
EN61000-4-2 ESD - levels ±4kV contact, ±8kV air discharge
EN61000-4-4 fast transients on mains input - levels ±2kV
EN61000-4-5 surges - levels ±2kV line to earth, ±1kV line to line
EN61000-4-8 magnetic fields - levels 30A/m at 50/60Hz
EN61000-3-2 limits for harmonic current emissions
EN61000-4-11 voltage dips, interruptions
The unit will not trip and recovers to normal operation after a disturbance as defined in SEMI F47.
The EMC performance of the power supply can only be fully assessed when installed within, and as a part of, the final system.
Cooling Fan assisted with fan fail detection.  Air inlets at the front of the unit, exhaust on the rear of the unit.  Minimum air flow required is 3m/s at the input to the fan
For slide and shelf mounting a 25mm gap must be provided at the front and the rear of the unit for air exhaust.  No gap above or below the unit is necessary.

 

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.