The miniature, micro-sized M series is the ideal solution for applications that need a biasing voltage ranging from 0 to 3000 V and very small volume, at only 1.00 in³ (16.4 cc). At less than 0.5 in (12.7 mm) in height, these modules are ideal for low-profile applications.

Model-Specific Downloads

M series brochure    JAPANESE
M series brochure    KOREAN
M series data pack
Interfacing with the UltraVolt M and V series of micro-sized high voltage power supplies
 

Typical Applications Features
  • Bias supplies
  • Electrostatic chuck (e-chuck)
  • Hand held x-ray florescence (XRF)
  • Avalanche photo diodes (APD)
  • Photomultiplier tubes (PMT)
  • Silicon detector (SiD)
  • X-ray flat panel detector (FPD)
  • Ionization chamber detector
  • Seven models from 0 to 600, 1000, 1250, 1500, 2000, 2500, or 3000 V
  • 0.5, 0.8 or 1 W output power
  • Tight line/load regulation
  • Arc and continuous short circuit protection
  • Self-restoring output voltage
  • Low cost
  • Miniature and light weight
  • Voltage monitoring
  • Low ripple (0.01% peak to peak)
  • Optional flying lead for high voltage output
Specifications
Input voltage VIN (pins 1 & 2) 5 VDC ± 0.5 (2-3 kV only)
12 VDC ± 1
15 ± 1 (600 V-1.5 kV only)
24 VDC ± 2
Input current 5V (2 to 3 kV only)
12 V
15 V (600 V-1.5 kV only)
24 V
Polarity  Fixed positive and fixed negative
Output voltage 0 to 600 VDC 0 to 1000 VDC 0 to 1250 VDC 0 to 1500 VDC
     Input voltage (VDC) 12 15 24 12 15 24 12 15 24 12 15 24
     Output power (W) 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1
     Output current (mA) 0.83 1.33 1.67 0.5 0.8 1 0.4 0.64 0.8 0.33 0.53 0.67
Output voltage 0 to 2000 VDC 0 to 2500 VDC 0 to 3000 VDC
     Input voltage (VDC) 5 12 24 5 12 24 5 12 24
     Output power (W) 0.5 0.8 1 0.5 0.8 1 0.5 0.8 1
     Output current (mA) 0.25 0.40 0.50 0.20 0.32 0.40 0.167 0.267 0.333
HV setting 10 K to 100 K (potentiometer across VREF and signal ground, wiper to adjust)
Load voltage regulation  <0.01% of full output voltage for no load to full load
Line voltage regulation  <0.01% of full output voltage over specified input voltage range
Residual ripple  <0.01% at full load
Output HV monitoring
(600 V to 1500 V)
+1 V / 1 kV max or -1 V / -1 kV max according to model polarity output impedance = to 200 kΩ ±1%
Output voltage monitoring
(2 kV to 3 kV)
12 to 24 VDC input only: 0 to 5 V ±2%
5 VDC input: 0 to 2.5 V ±2%
Output reference voltage 12 to 24 VDC input only: 5 V ±1%, TC: 100 ppm/°C, max output current: 1 mA
5 VDC input only: 2.5 V ±1%, TC: 100 ppm/°C, max output current: 1 mA
Options Flying lead for HV output
Suitable for use with an external potentiometer
Enhanced interface (-EI) option
(2 kV to 3 kV only)
Enable/disable (ON/OFF): 0 V to +0.5 V Enable, +2.4 V to V_input disable (default=disable)
Output current monitor (5 V input only): 0 to 2.5 V ±2%
Output current monitor (12 to 24 V input): 0 to 5.0 V ±2%

Interlocks and Limits
Limits Arc and short circut limits

Cooling
 Temperature coefficient  <100 ppm/°C for max output voltage after starting and over temperature range 0 to 50°C
 Operating temperature  -10 to +65°C, full load, max Eout, case temp
Storage temperature  -40 to +70°C

 

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.