For a sales quote, meeting request, evaluation unit, or other sales question, please fill in the form below:


Terms of Use | Privacy Policy
HITEK POWER® XR150
Photo of XS Series Power Supply
   

X-RAY POWER SUPPLY MODULE

Specifically developed for high-performance x-ray applications, the compact and reliable XR150 series is surface mountable and built with superior high voltage stress control and packaging techniques. The filament is automatically controlled by integral beam loop control and the power stage utilizes a current-fed resonant push-pull converter to provide high efficiency and reliability.

Model-Specific Downloads

XR150 series brochure
XR150 series brochure   GERMAN
Download CAD .sat file
Download CAD .stp file
 
Features Typical Applications
  • 150 W high voltage output
  • 17 W floating filament
  • High accuracy and stability
  • ---- Emission accuracy: 0.1%
  • ---- Regulation: 0.1%
  • ---- Stability: 100 ppm
  • Exceptionally compact
  • Remote operation
  • Analog or RS-232 control interface
  • Safety interlock
  • Extensive tube and system protection functions
  • CE marked for EU LV directive 2006/95/EC
  • EU RoHS compliant to 2002/95/EC
  • Inspection and analytical x-ray systems with floating filament tubes
  • ---- X-ray fluorescence (XRF)
  • ---- X-ray diffraction (XRD)
  • ---- X-ray reflectivity (XRR)
  • ---- X-ray imaging (XRI)
  • Industrial process x-ray systems
  • ---- Elemental analysis equipment
  • ---- Process quality, safety, compliance
  • ---- Materials monitoring
  • ---- Food safety inspection
  • Digital x-ray imaging and inspection
  • ---- Industrial
  • ---- Veterinary
  • ---- Pharma, cellular, biotech,
  • ---- Security
Specifications
Electrical input
Voltage 24 VDC ±1 VDC
Current 11 A, max
Electrical output
Voltage 0 to -60 kV; full spec applies above -3 kV
Current 0 to -2.5 mA
Power 150 W, max
Ripple < 100 V, peak to peak
Filament
           0 to 3.7 A (4.5 V, max)
Controlled by internal beam control loop
Controls (analog version)
Voltage demand 0 to 5 VDC demands 0 to -60 kV ±0.5% ±100 V
Current demand 0 to 5 VDC demands 0 to -2.5 mA ±2% ±5 μA
Filament limit Internally settable between 1 and 3.7 A
Controls (RS-232 version)
Output voltage 0 to 5 VDC demands 0 to -60 kV ±0.5% ±100 V
Current demand 12 bit; 0 to FFF demands 0 to -2.5 mA ±2% ±5 μA
Filament standby 12 bit; 0 to FFF demands 0 to 3.7 A
Monitors (analog)
Output voltage 0 to 5 V ±0.5% ±20 mV for 0 to -60 kV
Beam current 0 to 5 V ±2% ±20 mV for 0 to -2.5 mA
Filament current 0 to 5 V ±5% ±20 mV for 0 to 3.7 A
Filament voltage 0 to 5 V ±5% ±20 mV for 0 to 5 V
Monitors (RS-232)
Output voltage 12 bit; 0 to FFF represents 0 to -60 kV
Output current 12 bit; 0 to FFF represents 0 to -2.5 mA
Filament current 12 bit; 0 to FFF represents 0 to 3.7 A
Filament voltage 12 bit; 0 to FFF represents 0 to 5 V
Load regulation, output voltage
Static < 60 no load to full load
Dynamic < 3 kV, recovery to within 1% of previous setting within 200 msec
Beam current < ±2 μA for a 10 to 100% of change of rated load
Line regulation
Output voltage < 60 V for a 1 V change in the 24 V supply
Beam current < ±2 μA for a 10 to 100% of change of rated load
Stability and drift
Temperature coefficient 100 ppm/°C over operating temperature range
Drift ±0.1% of rating over an eight-hour period after 30 min warmup
Environmental
Operating temperature 0 to +40°C (+32 to +104°F)
Storage temperature -20 to +85°C (-4 to +185°F)
Humidity 80% maximum relative humidity up to 31°C (88°F), reducing linearly to 50% at 40°C (104°F), non-condensing (ref BS EN61010-1)
Vibration In accordance with BS EN60068-2-6:1995 transport, when contained in the original packaging
Frequency range 10 to 500 Hz
Acceleration 20 m/sec² crossover at 58 Hz
Displacement 0.15 mm (0.006") max
Altitude 0 to 2000 m (0 to 6562')
Installation environment Installation category 1, pollution degree 2, indoor use only
Cooling Fan assisted
Connectors
Input DC power Deutsch IMC24-1602
HV output HiTek Power®-designed detachable poke home connector
Filament output HiTek Power®-designed detachable poke home connector
Control interface 15-way, D-type socket (analog)
9-way, D-type socket (RS-232)
Protection, Safety, and Compliance
Protection Input voltage reverse polarity
Over-temperature
Over-current (continuous short circuit and intermittent arc) on both HV output and filament
Over-voltage on both HV output and filament
Safety This high voltage module meets the requirements of the Low Voltage Directive (LVD), 2006/95/EC by complying with BS EN61010-1:2001 when it is installed as a component part of other equipment and is CE marked accordingly.
EMC This high voltage module is intended for installation as part of a system.
Basic EMC filtering is provided.
RoHS The XR150 meets the requirements of the EU Directive 2002/95/EC on the restriction of use of certain hazardous substances in electrical and electronic equipment (RoHS).
 




Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.