E Series
Photo of XS Series Power Supply

Single-Output Precision High Voltage Power Supply Module

The E series of precision high voltage power supplies has very low ripple, excellent linearity, and very stable temperature characteristics. Models in this series are offered at two levels of performance; the best delivers 10 ppm characteristics. This series is ideal for applications where system performance is directly linked to high voltage power quality and performance.

Model-Specific Downloads

E series brochure     JAPANESE
E series data pack
Interfacing with the E Series Precision High Voltage Power Supply
 

Typical Applications Features
  • Bias supplies
  • Mass spectrometry
  • SEM/FIB
  • Electron beams
  • Ion beams
  • Precision output voltage from
  • 0 to 1 kV through 0 to 15 kV
  • PPM level ripple, regulation and stability
  • As low as 10 ppm temperature coefficient and reference
  • 0 to 4, 15/20, or 30 W of output power
  • Maximum Iout capability down to 0 V
  • Voltage and current regulation/limit capability
  • Precision output voltage and current monitors
Specifications
Input voltage range 23 VDC to 30 VDC full power
Input current Standby/disable: <50
No load, max EOUT: <325
Full load, max EOUT: 2.5
AC ripple current <10 nominal input, full load
Output 1E 2E 4E 6E 10E 15E
Output voltage range 0 to 1,000
VDC
0 to 2,000
VDC
0 to 4,000
VDC
0 to 6,000
VDC
0 to 10,000
VDC
0 to 15,000
VDC
Nominal input voltage/model 24 24 24 24 24 24
Output power (W) 4 20 30 4 20 30 4 20 30 4 20 30 4 15 30 4 15 30
Output current (mA) 4 20 30 2 10 15 1 5 7.5 0.67 3.3 5 0.4 1.5 3 0.26 1 2
Voltage monitor 0 to 10 ±0.5% for normal operating conditions
Current monitor 0 to 10 ±0.5% for normal operating conditions
Ripple ≤10 for full load, max EOUT
Line regulation <25 ppm or <10 ppm for nom input, max EOUT, full power
Static load regulation <25 ppm or <10 ppm for no load to full load, max EOUT
Stability <25 ppm or <10 ppm for 30 min warmup, per 8 h, per day

Programming and Controls

Input impedance 10 for nominal input
Adjust accuracy and adjust linearity ±0.05% for 10 to 100%
Adjust voltage 0 to +10 for differential
Output voltage +10.00 ±0.05% for T = +25°C, Initial Value
Max source current 5 for T = +25°C
Output impedance Buffered, low impedance, 2 mA max for source/sink current for normal operating conditions
Enable/disable 0 to +0.8 disable, +2.5 to 10 enable (default = disable)

Environmental
Operating +10 to +45 for full load, max EOUT, case temp.
Temperature coefficient ±25 or ±10 over the specified temperature
Thermal shock -40 to +65 for Mil-Std-810, Method 504, Class 2
Storage -55 to +105 for non-operating, case temp.
Humidity 0 to 95%, non-condensing for all conditions, standard package
Altitude Sea level through 10,000 for standard package, all conditions
Shock 20 for Mil-Std-810, Method 516, Proc. 4
Vibration 10 for Mil-Std-810, Method 514, Fig. 514-3

 

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.