For a sales quote, meeting request, evaluation unit, or other sales question, please fill in the form below:


Terms of Use | Privacy Policy
AA Series
Photo of AA Series Power Supply
   

Single-Output High Voltage Modules

The AA series consists of high voltage, miniature PCB-mount, regulated DC-DC converters. Designed and built utilizing state-of-the-art power-conversion topology, these units feature surface-mount technology and encapsulation techniques that provide high reliability and performance.

The AA Series is also available with enhanced interface options. Download the –I5/-I10 Options data sheet to find out more information about these options.

Model-Specific Downloads

AA series brochure    
AA series brochure   JAPANESE   
AA series brochure   SIMPLIFIED CHINESE
AA series data pack
Interfacing with UltraVolt high voltage power supplies: A, AA, C, 10A-25A, 30A-40A, and F series
 


 
Typical Applications Features
  • Bias supplies
  • Detectors
  • Piezos
  • Amplifiers
  • Photomultiplier tubes (PMT)
  • 22% smaller than standard A series
  • 8 models from 0 to 62 V through 0 to 6 kV
  • 4, 20, or 30 W output power
  • Max Iout capability down to 0 V
  • Wide input voltage range
  • Indefinite output short-circuit protection
  • Output current and voltage monitors
  • Fixed-frequency, low-stored-energy design
  • UL/cUL recognized component; CE Mark (LVD & RoHS)
Specifications
1  
Input Conditions 12 V 24 V
Voltage range Full power +11 to 16 VDC +23 to 30 VDC
Voltage range Derated power range +9 to 32 VDC +9 to 32 VDC
Current Standby / disable < 30 mA < 30 mA
Current No load, max EOUT < 100 mA (4 W) 150 mA (20 and 30 W)
Current Max load, max EOUT < 450 mA (4 W) < 1000 mA (20 W)                            
< 1500 mA (30 W)
AC ripple current Nominal input, full load < 80 mA peak to peak < 80 mA peak to peak
Output    1/16AA 1/8AA 1/4AA 1/2AA
Voltage range (VDC) Nominal input 0 to 62 0 to 125 0 to 250 0 to 500
Nominal input voltage / model (VDC)   12 24 24 12 24 24 12 24 24 12 24 24
Power (W) Nominal input, max EOUT 4 20 30 4 20 30 4 20 30 4 20 30
Current (mA) IOUT entire output voltage range 64 320 480 32 160 240 16 80 120 8 40 60
Current scale factor (mA)/V Full load 42.67 969.7 960 11.64 237 258 3.27 70.48 72.7 0.79 17.78 17.65
Voltage monitor scaling   10:1 ± 2% into 10 MΩ
Ripple (%V peak to peak) Full load, max EOUT 0.03 0.06 0.15 0.03 0.038 0.038 0.023 0.04 0.05 0.01 0.01 0.011
Output    1AA 2AA 4AA 6AA
Voltage range (VDC) Nominal input 0 to 1000 0 to 2000 0 to 4000 0 to 6000
Nominal input voltage / model (VDC)   12 24 24 12 24 24 12 24 24 12 24 24
Power (W) Nominal input, max EOUT 4 20 30 4 20 30 4 20 30 4 20 30
Current (mA) IOUT entire output voltage range 4 20 30 2 10 15 1 5 7.5 0.67 3.3 5
Current scale factor (mA)/V Full load 0.37 4.60 4.62 0.192 1.52 1.52 .090 0.752 0.76 0.067 0.490 0.50
Voltage monitor scaling   100:1 ± 2% into 10 MΩ
Ripple (%V peak to peak) Full load, max EOUT 0.2026 0.048 0.073 0.01 0.011 0.046 0.042 0.050 0.070 0.035 0.024 0.046
Output (bipolar) Nominal input ±25 VDC ±50 VDC ±75 VDC ±100 VDC ±125 VDC ±150 VDC
Voltage range proportional (VDC) X to 105%, model specific ±12.5 to ±26.25 ±25 to ±52.5 ±37.5 to ±78.75 ±50 to ±105 ±62.5 to ±131.25 ±75 to ±175.5
Power (W) Nominal input, max EOUT 1.5 3 1.5 3 1.5 3 1.5 3 1.5 3 1.5 3
Current (mA) IOUT entire output voltage range 30 60 15 30 10 20 7.5 15 6 12 5 10
 
Line regulation Nominal input, max EOUT, full power < 0.01 %
Static load regulation No load to full load, max EOUT < 0.01%
Stability 30 min warm up, 8 hr/ per day < 0.01%  /  < 0.02%
Programming & Controls
Input impedance Nominal input + Output Models 1.1 MΩ to GND
- Output Models 1.1 MΩ to +5 Vref
Adjust resistance Typical potentiometer values 10 K to 100 K (Ppt across Vref. & signal GND, wiper to adjust)
Adjust logic 0 to +5 for +Out
+5 to 0 for -Out
+4.64 VDC for +Output
+0.36 for -Output = Nominal EOUT
Output voltage & impedance T=+25°C + 5.00 VDC ± 2%, ZOUT = 464 Ω ± 1%
Enable/Disable   0 to +0.5 disable
+2.4 to 32 enable (default = enable)

Environmental
Temperature coefficient Over the specific temperature  ±50 (±25 optional) PPM/°C 
Operating temperature Full load, max EOUT, case temperature -40 to +65°C
Storage temperature Non-operating, case temperature  -55 to +105°C
Humidity All conditions, standard package 0 to 95% non-condensing
Altitude Standard package, all conditions Sea level through vacuum
Shock Mil-Std 810, method 516.5, Proc. IV 20 Gs
Vibration Mil-std-810, method 514.5, fig.514.5C-3 10 Gs

 

Accuracy of specifications in unlocked documents cannot be guaranteed. Please contact your AE representative to confirm specifications.